Connecting the Boditech AFIAS 6 to your LIS or EHR
An immunoassay analyser on the bench gives you a cardiac marker, a thyroid result, or a CRP in minutes, but the value still has to reach the systems your clinic runs on. Where that last step is manual, someone reads the number off the AFIAS 6 screen or a printout and keys it into the patient record. That takes time, it is easy to transpose a digit, and the record of who did what can be thin.
This page explains, in plain terms, how a Boditech AFIAS 6 can send its results into a laboratory information system (LIS) or electronic health record (EHR), and what Catenix does in the middle so that results flow automatically and quality-control data stays where it belongs.
Quick answer
The Boditech AFIAS 6 reaches the network through its own host interface. Catenix is designed to connect to that interface, capture the results at your site with a small on-site gateway, keep quality-control runs separate from patient results, preserve an audit trail, and forward the patient results to your LIS or EHR. You avoid manual transcription and keep a clear record of what was received.
| Aspect | What Catenix supports |
|---|---|
| Device type | Cartridge-based fluorescence immunoassay analyser |
| Interface family | The AFIAS host interface (result messages from the analyser) |
| Transport | Over the site network (TCP/IP) |
| Direction | Results in, from the analyser to Catenix |
| Quality control | QC runs identified and held separate from patient results |
| Onward delivery | Patient results can be pushed to a LIS or EHR |
What the Boditech AFIAS 6 measures
The Boditech AFIAS 6 is a benchtop, cartridge-based fluorescence immunoassay analyser. A single-use cartridge is loaded for each test, and the menu available depends on which cartridge is used. Across the cartridge range it can report markers such as cardiac markers, thyroid function, fertility hormones, and markers of inflammation (for example CRP, TSH or HbA1c, depending on the cartridge).
Catenix does not change what the device measures or how it is operated. Our scope is connectivity: taking the results the analyser already produces and moving them reliably into your other systems. We make no claim about the device's clinical performance or its suitability for any diagnostic decision.
How the AFIAS 6 connects
The AFIAS 6 presents its results to the wider network through a manufacturer host interface. On its public data sheets, the analyser can send completed results to a host system over the network, the same general pattern used across much of point-of-care testing for passing results between an instrument and the systems around it.
Catenix is designed to connect to that host interface. In broad terms, each result message carries the identifying details of a test event and the values that go with it, structured so that a receiving system can file them against the right record. Catenix speaks this general interface. We do not need, and this page does not publish, any vendor-specific internal detail about how individual values are laid out.
At your site, a small Catenix gateway sits on the local network and receives the result messages the AFIAS 6 sends over the analyser host interface. The gateway is the only piece of new hardware involved, and it runs quietly alongside your existing kit.
Results and quality control in Catenix
Once the gateway receives a result, Catenix records it in your cloud workspace with a timestamp and keeps an audit trail of what arrived and when. Nothing is retyped, so the value in the record is the value the analyser produced.
Point-of-care analysers also produce quality-control runs, the checks that confirm the device and cartridges are behaving as expected. Catenix identifies these QC runs and keeps them separate from patient results, so a control sample never lands in a patient's record and your QC history stays intact for review. This separation is worked out from the information in the incoming results, without any change to how the analyser is used.
From there, Catenix can forward the patient results onward to the systems your site already runs, such as a LIS or an EHR. The result flows once, automatically, from the analyser through to the record, and the same audit trail follows it.
Getting connected
To connect an AFIAS 6, a site typically needs the analyser host interface configured to send results over the network, a Catenix gateway on that same network, and agreement on where patient results should be delivered. Most of the setup is configuration rather than new equipment.
If you are planning a connection or want to check what your current setup allows, our team can talk it through with you. See /contact/ to get in touch, /platform/ for how the workspace and gateway fit together, and /pricing/ for how it is packaged. For security and data handling, see /security/ and /trust/.
Questions clinics ask
Can I connect a Boditech AFIAS 6 to my LIS?
Yes. The AFIAS 6 offers a host interface over the network, and Catenix is designed to connect to it, capture the results, and forward them to a LIS or EHR. The main requirement is that the analyser is set to send results to a host and that a Catenix gateway is on the same network.
Do I need new hardware to make this work?
The only new item is the small Catenix gateway that sits on your local network. The AFIAS 6 carries on as it is, and most of the work is configuration rather than installation.
How are quality-control runs handled?
Catenix recognises QC runs in the incoming results and keeps them separate from patient records. Your control results stay grouped for review and never appear against a patient, which keeps both the patient record and the QC history clean.
Will results still be transcribed by hand?
No. Once the connection is live, results move from the AFIAS 6 into Catenix and onward automatically, so nobody rekeys a value. An audit trail records what was received and when.
Which cartridges or tests are supported?
Catenix carries whatever result the AFIAS 6 sends, so the tests available depend on the cartridges your site runs rather than on Catenix. We handle the connectivity, not the measurement itself.
How do we get started?
Get in touch through /contact/ and we can review your current setup, the AFIAS 6 host-interface configuration, and where you want results delivered. See /platform/ for how the gateway and workspace work together.
Product and company names mentioned are the trademarks of their respective owners. Reference to them is for identification only and does not imply any affiliation with, endorsement by, or certification from those owners. This page describes connectivity and data handling only and is not clinical advice.
Reviewed July 2026. Back to integrations. Going deeper on the standard: our guide to connecting an analyser to a LIS.
Running something we have not listed?
We build analyser drivers to order, including for niche, regional and discontinued instruments. Tell us the make and model and we will tell you what is possible. Custom integrations or request a quote.