Setting up a private laboratory in the UK: regulation, accreditation and systems
More private blood testing services, clinics and clinic groups are bringing testing in house rather than sending every sample to a reference lab. This guide walks through what opening a private medical laboratory in the UK involves: the regulators, accreditation, analysers, quality, people, data and the systems that hold it all together.
Written and reviewed by the Catenix team. How these guides are written and checked.
In brief
- In England, providing diagnostic and screening procedures to patients generally requires CQC registration; the devolved nations have their own regulators.
- UKAS accreditation to ISO 15189:2022 is not compulsory for every lab, but clinics, insurers and NHS commissioners increasingly expect it; plan for it from day one.
- Choose analysers with the test menu, throughput and connectivity in mind; every analyser should send results to your system without typing.
- Quality means internal QC with Westgard rules, EQA enrolment, method verification, competency and an audit trail, held together in one system.
- Catenix gives a new UK lab analyser connectivity, QC, review, reports, delivery to clinics and patients, and ISO 15189 evidence in one platform, with hosting arranged to meet your local data requirements.
Take it with you: POCT connectivity buyer's guide · POCT readiness checklist (PDF, no form).
Why private providers bring testing in house
Sending samples to a reference lab is simple, but it costs margin on every test and adds turnaround time. Once volume grows, an in-house lab can return common results the same day, control the patient experience end to end, and open new services such as partner-clinic testing. The trade-off is responsibility: the lab must show that every result is accurate, traceable and released by a competent person.
Regulation and registration
CQC. In England, carrying on the regulated activity of diagnostic and screening procedures generally requires registration with the Care Quality Commission, with a registered manager and evidence that the service is safe, effective, caring, responsive and well led. Scotland (Healthcare Improvement Scotland), Wales (Healthcare Inspectorate Wales) and Northern Ireland (RQIA) have their own arrangements. Check the guidance for your exact model, because collection-only services, testing services and services that interpret results for patients are treated differently.
Medical devices. Analysers and reagents are in vitro diagnostic medical devices regulated by the MHRA. Use them within their intended purpose; modifying a method makes you responsible for validating it.
Data protection. Register with the ICO, appoint someone responsible for data protection, carry out a data protection impact assessment, and have contracts in place with every processor, including your software vendor.
UKAS accreditation to ISO 15189:2022
UKAS accredits medical laboratories against ISO 15189:2022. The process typically runs from application through document review, a pre-assessment if you choose one, the initial assessment, closing any findings, and the grant of accreditation for a defined scope of tests. You need a working quality management system and real operating records before assessment, so labs usually run for a period first.
Building for accreditation from the start avoids rework. The things an assessor looks for, and that your systems should hold, include:
- method verification records for each analyser and test
- internal QC with defined rules and documented responses
- EQA participation and review for every test in scope
- staff training, competency and authorisation
- equipment maintenance, calibration and temperature records
- document control, nonconformities, corrective actions and internal audit
- risk management and management review
- traceability from request to report
Our ISO 15189 guide explains the 2022 version, and our guide to verifying a new analyser covers verification.
Choosing analysers
Start with the test menu your clients want, then consider throughput, sample type, footprint, reagent supply and service in the UK. Ask every supplier the connectivity questions too: which protocol the analyser uses (ASTM E1394, HL7 v2 or POCT1-A2), whether it supports bidirectional host query so it can ask your system which tests to run for a barcode, and whether QC results are flagged as QC in the output. A great analyser that only prints results will cost you hours of typing every day. Our analyser connection guides and the open connectivity dataset list the protocol and interface notes for 130 analysers, so you can check before you buy.
People and competency
A UK private lab typically needs HCPC-registered biomedical scientists for the testing that requires them, a person with overall scientific responsibility, and clear authorisation for who may release which results. Competency should be assessed and recorded per person and per analyser, with retraining tracked. Your system should be able to stop someone releasing results for a test they are not authorised for. See our operator competency guide.
The systems a new lab needs
| Need | What it covers |
|---|---|
| Registration and requests | Patients, partner clinics, request forms, accession numbers and labels |
| Analyser connectivity | Results from every analyser without typing, bidirectional where possible |
| QC and EQA | Levey-Jennings charts, Westgard rules, lockout, EQA records |
| Review and release | Results checked and released by authorised staff, with an audit trail |
| Reports and delivery | Branded reports to clinics, GPs and patients; integration with clinic EHRs |
| Quality management | Documents, nonconformities, corrective actions, audits, equipment logs |
| Billing | Price lists, packages and invoices for patients and partner clinics |
Many new labs buy these as separate tools and join them with spreadsheets. That works until the first assessment, when nobody can show that a given result was released after its QC passed. One platform that holds results and quality records together avoids the gap. See choosing a LIS for a private lab in the UK.
A realistic timeline
- Define services, test menu and target clients.
- Secure premises, utilities, waste and health and safety arrangements.
- Choose analysers and software together, so connectivity is settled before delivery.
- Register with CQC or the relevant regulator and the ICO.
- Install, verify methods and set up QC rules and EQA.
- Train staff, assess competency and authorise release.
- Validate the end-to-end flow: request, sample, analyser, review, report, delivery.
- Go live, gather operating records, then apply for UKAS accreditation.
What to budget for
Costs vary too much by service model for a single figure to be useful, but the lines are predictable. Price each one before you commit to premises:
| Cost line | Notes |
|---|---|
| Analysers | Purchase, lease or reagent rental; service contract; installation and verification support |
| Reagents, calibrators and controls | Ongoing; controls are often forgotten in early budgets |
| Lab software | Subscription or licence, interfaces, implementation and training |
| Connectivity hardware | A PC or small device for the gateway; serial adaptors for older analysers |
| EQA schemes | A subscription for each test or group of tests in scope |
| Accreditation | UKAS application and assessment fees, from its published fee schedule |
| Registration | CQC or the relevant regulator, and the ICO data protection fee |
| People | Biomedical scientists, a quality lead, and time for training and competency |
| Premises | Fit-out, utilities, waste contracts, temperature control and security |
Mistakes new labs make
- Buying analysers before checking connectivity. An analyser that cannot send results electronically locks in manual entry.
- Opening before the validation evidence exists. Method verification and end-to-end testing come before the first patient.
- Quality documents without quality records. Procedures in a folder do not help if QC, competency and maintenance live in scattered spreadsheets.
- Underestimating EQA. Every test in scope needs a scheme, or an alternative assessment where none exists.
- Promising partner clinics a delivery route before it is built. Agree the route and test it first.
A day-one systems checklist
- Every analyser connected, with a traced first result and QC filed as QC.
- Test catalogue with units, ranges and comments approved by the person with scientific responsibility.
- Report templates approved for each partner clinic.
- Every user with their own login, role and competency record.
- Temperature monitoring and maintenance schedules running. See quality and governance.
- Nonconformity log and document control in use.
- Data protection impact assessment completed and processor contracts signed.
- A tested plan for an internet or power outage.
Where Catenix fits
Catenix gives a new UK lab most of the systems in the table above in one platform: registration and accession numbers, analyser connectivity over ASTM E1394, HL7 v2 and POCT1-A2, QC with Westgard rules and lockout, EQA, competency, equipment and nonconformity records, review and release, branded reports per partner clinic, signed reports filed into Semble and results to any clinic system that accepts a standard HL7 v2 or FHIR result, and billing. Hosting is arranged to meet your local data requirements, including in-country hosting where required, pricing is per site with no per-test fees, and set-up takes days for analysers Catenix already supports. Catenix is connectivity, workflow and record-keeping software; it does not interpret results and is not marketed as a medical device, and accreditation decisions remain with UKAS.
Questions people ask
Do I need UKAS accreditation to open a private lab?
Not always as a legal requirement, but many clients, insurers and NHS commissioners expect it. Build your quality system for ISO 15189:2022 from the start so you can apply once you have operating records.
How long does it take to open a private lab in the UK?
It depends on premises, regulator registration and staff, but the lab and software set-up itself can be done in weeks once analysers are on site. Accreditation follows after a period of operation.
Does a private lab need CQC registration?
Services in England that carry on diagnostic and screening procedures for patients generally need to register. Check CQC's guidance for your service model.
Which software does a new private lab need?
Registration, analyser connectivity, QC and EQA, review and release, reporting and delivery, quality management and billing. One platform that covers them avoids gaps at assessment.
Can Catenix host data in the UK?
Hosting is arranged to meet your local data requirements, including in-country hosting where required.
What should we check before buying analysers for a new lab?
The test menu, throughput, reagent supply and UK service, plus connectivity: which protocol the analyser uses, whether it supports host query, and whether QC results are marked as QC in its output.
When can a new lab apply for UKAS accreditation?
Once the quality management system is running and there are real operating records to assess, including QC, EQA, competency and audit records. Many labs operate for a period before applying, and UKAS can advise on timing.
Sources and further reading
Read next
More for coordinators.
Analyser connection guides
Step-by-step guides to connecting point-of-care and lab analysers to your LIS or EHR over HL7, POCT1-A2 and ASTM, with bidirectional, wire-level...
Read →Choosing a LIS for a private lab in the UK
How to choose laboratory software for a UK private lab: UKAS ISO 15189 evidence, CQC, analyser connectivity, GP and NHS delivery, data protection and...
Read →ISO 15189:2022 and point-of-care testing
What ISO 15189:2022 means for point-of-care testing: how Annex A absorbed ISO 22870, the records assessors expect, and how software supports the...
Read →Take it with you
The buyer's guide, in your inbox.
Nine pages on what POCT connectivity is, the standards in plain English, the cost of doing it by hand and eight questions to ask any supplier.
Get the POCT connectivity buyer's guide
Nine pages, vendor-neutral: what connectivity is, the standards in plain English, the cost of doing it by hand and eight questions to ask any supplier. The PDF also opens directly from the downloads page; leave an email only if you want it in your inbox.
See it done in software.
A 30-minute walkthrough on a live tenant, with your analysers and your allowable-error limits.