Home / Insights / Laboratory

Reagent lot and expiry tracking for small labs: from stock list to recall in minutes

LaboratoryPublished 2026-11-207 min readInternational

Inventory is the LIMS feature small labs think they can live without, right up until a manufacturer withdraws a reagent lot. Then the question is not "how many boxes do we have" but "which patients' results were produced with it". This guide covers what lot and expiry tracking should do in a clinic or small lab, how it connects to QC and results, and where it lives if you already run another system.

Written and reviewed by the Catenix team. How these guides are written and checked.

In brief

  • Inventory in a lab is about lots and expiry dates, not just counts. QC and traceability both depend on knowing which lot was in use.
  • Good software tracks stock by site, storage location and device, and surfaces low stock and approaching expiry before a clinic morning.
  • The step most systems miss is linking a lot to the results produced while it was loaded, so a recall becomes a list rather than an investigation.
  • Catenix holds inventory and lot traceability in the same record as results and QC, whether it acts as your lab record or sits underneath the LIS or EHR you already use.

Take it with you: POCT connectivity buyer's guide · POCT readiness checklist (PDF, no form).

Why a stock spreadsheet is not enough

Most small labs keep stock in a spreadsheet or on a whiteboard by the fridge. It tells you roughly how many cartridges are left. It does not tell you that the HbA1c control lot on the second analyser expires on Thursday, or that the branch across town opened a new box of strips with a different lot number last week.

Those details matter for two reasons. First, QC is run per lot. A new control lot needs its own targets, and a run against an expired control is not evidence of anything. Second, results are produced with a specific reagent lot loaded. If that lot turns out to be faulty, the lab has to find every result it touched.

What lot and expiry tracking should cover

  • Stock levels by site and storage location, so a group can see each clinic's fridge separately.
  • Lot and batch numbers with expiry dates, recorded when stock arrives.
  • Low-stock and approaching-expiry warnings that appear before the problem, not on the morning it happens.
  • Consumption linked to devices, tests and packages, so usage matches the work actually done.
  • A network view for a coordinator overseeing several sites.

Catenix covers each of these on the inventory module, in the same audited system as results and QC.

When a new control lot arrives

New control lots are where stock and quality meet. Picture a clinic running lipids on a Roche cobas b 101. The current control lot runs out at the end of the month, and a fresh box arrives with a different lot number and different target values. If the new lot goes into the fridge without being recorded, the first QC run against it is compared with the old targets, and either fails for no reason or passes when it should not.

Recording the lot on arrival, with its expiry date, means the change is visible before it is used. The team can set up the new lot's targets, run it in parallel with the old one if their procedure calls for it, and switch over on a known date. The QC record then shows exactly when the change happened. For the rules behind QC review, read Westgard rules explained for POCT teams.

Linking lots to results: usage windows

The idea is simple. A lot is installed on a device and removed when it is replaced. The time between those two moments is the lot's usage window on that device. Any result produced on that device inside the window was produced with that lot.

In Catenix, usage windows can be entered by hand or synchronised nightly from the stock register. Open any result and you see the reagent, control and calibrator lots that were on the analyser when it ran. Go the other way and pick a lot, and you see every result produced while it was in use, by device and date. The lot traceability page shows the detail.

A recall, worked through

Say a manufacturer issues a field safety notice for a lot of CRP cartridges. Without traceability, someone pulls delivery notes, asks each branch what they had loaded and when, and searches results by date range. It takes days and still leaves doubt.

With usage windows recorded:

  1. Log the notice and the lot pattern it covers.
  2. Affected devices, controls and consumables appear from the live registers, and the traceability view lists every result produced under the lot.
  3. Export the impact list to CSV, contact the right clinicians, quarantine the stock, and record the actions against the notice or a non-conformance.
  4. Close the recall. The notice, the list and the actions stay linked in the audit trail.

The clinical follow-up is a decision for your clinicians. The software's job is to make sure they start with a complete list.

A side benefit: cost per test

Once consumption is linked to devices and tests, cost per test falls out of the data. Catenix rolls stock cost up by device and analyte, which helps when a service lead has to justify a new analyser or renegotiate a reagent contract. It is the same data, used for a second purpose.

Where inventory lives if you already have a LIS or EHR

Inventory is often missing from clinic EHRs and patchy in older LIS products, which is why labs keep it in a spreadsheet beside them.

  • If Catenix is your lab record, inventory, QC, results and traceability are already one system. Read Catenix as your LIMS for the full picture.
  • If you keep your LIS or EHR, Catenix can still hold inventory and lot traceability as the layer between the analysers and that system. Results continue to flow to your record of choice; the stock, lot and QC evidence sits in Catenix, joined to each result.

What to check before buying

QuestionWhy it matters
Can we see expiry per lot, per site?Avoids running QC or patients on expired material
Is each result linked to the lots in use?Turns a recall into a query
Can the impact list be exported?Clinicians and managers need to act on it
Is stock tied to the device, not just the building?Groups move stock between analysers and sites
Does it share the audit trail with results?One record for inspection

Questions people ask

Is lot tracking really needed in a small clinic?

If you run QC or use reagents with expiry dates, yes. QC is tied to the control lot, and a recall is answered by knowing which lot was on which analyser when each result was produced.

How does Catenix know which lot was on an analyser?

Lots are installed on a device with a usage window, entered by hand or synchronised nightly from the stock register, and removed when replaced. Results are matched to the lots whose windows cover their timestamp.

Can Catenix warn us before stock expires?

Yes. Low-stock and approaching-expiry items are surfaced per site and device before they become a problem.

Do we need to replace our LIS to use Catenix inventory?

No. Catenix can hold inventory and lot traceability alongside the analysers while results keep flowing to your existing LIS or EHR.

Does Catenix tell us which patients to recall?

It lists every result produced while the lot was in use, with devices and patients. Which patients need follow-up is a clinical decision for your team.

Take it with you

The buyer's guide, in your inbox.

Nine pages on what POCT connectivity is, the standards in plain English, the cost of doing it by hand and eight questions to ask any supplier.

Get the POCT connectivity buyer's guide

Nine pages, vendor-neutral: what connectivity is, the standards in plain English, the cost of doing it by hand and eight questions to ask any supplier. The PDF also opens directly from the downloads page; leave an email only if you want it in your inbox.

We use your email only to send the guide and, if you ask, to follow up once. No newsletter unless you tick the box. See our privacy notice.

Thank you. The guide is on its way. You can also open it now.
That did not send. Open the guide directly or email contact@catenix.com.

See it done in software.

A demo on a live tenant, with your analysers and your allowable-error limits.

See how Catenix fits your lab

One platform for analyser connectivity, QC, results and records, sized for small labs and clinics. Book a demo with your own analysers in mind.

Live with clinics and labs in the UK and US. We reply within one working day.