Yes. The XN-1000 connects to a host computer over LAN using ASTM E1381 and E1394. It queries the host for patient demographics and orders, and Catenix answers with what was ordered in your EHR. It sends numeric results, flags, histograms and scatterplots, which Catenix keeps with the result.

The XN-1000 is a 5-part differential haematology analyser from the Sysmex XN-Series: a single analyser module with an SA-10 sampler holding five racks (50 samples), controlled by an IPU PC. It runs up to 100 samples an hour for CBC+DIFF, up to 83 with reticulocytes and up to 40 for body fluids.

It suits labs with a medium workload where 100 samples an hour is enough. Configurations add RET, PLT-F, WPC and body fluid analysis.

WhatHow Catenix handles it
Analyser type5-part diff haematology (XN-Series)
InterfaceASTM E1381 and E1394-91
Physical linkLAN (TCP/IP) to the host
OrdersHost query for orders and demographics
Data sentResults, flags, histograms, scatterplots, demographics
BarcodesCodabar, Code 39, Code 128

Host query on the XN-1000

When a rack is sampled, the XN-1000 asks the host for each tube's orders and demographics. Catenix replies with the EHR's tests and patient details, so the IPU shows the right work without manual entry. Results go back matched by sample ID, and anything unmatched waits for review.

Graphics and flags

Besides numbers, the XN-1000 sends flags, histograms and scatterplots. Catenix keeps every message with its result, so the full picture the analyser produced is part of the audit trail. Parameter codes are mapped to the EHR's codes at setup. The analyser itself stores 100,000 results including graphics.

The LAN link goes straight to the gateway on your network. It reconnects on its own after a network drop, and results produced during an internet outage are stored on site and forwarded later.

XN-1000 QC in Catenix

The XN-1000 keeps QC files with Levey-Jennings and XbarM on the IPU. Where control results reach the host, Catenix files them as QC, grades them with Westgard rules against your targets and holds patient results for a test whose QC fails.

Sysmex and XN-1000 are trademarks of their owners. Catenix is an independent connectivity provider, not affiliated with or endorsed by Sysmex.

Questions people ask

Does the Sysmex XN-1000 support host query?

Yes. It queries the host for orders and demographics, and Catenix answers from your EHR.

Does the XN-1000 send scattergrams to the LIS?

It sends histograms and scatterplots along with numeric results and flags. Catenix keeps them with the result.

How does the XN-1000 connect?

Over LAN to the host computer, using ASTM.

Related: Lab analyzer to EHR for small labs · Sysmex XN-550 connection · Sysmex CS-1600 connection · Device library

Product and company names are trademarks of their owners and are used for identification only. Catenix moves, stores and displays results with traceability; it does not interpret results or give clinical advice. Reviewed October 2026.

Tell us your setup

Send us your analyser and the system you want results in, and we will confirm how it connects, usually within one working day. Ask about your setup.